Liu Ying committed 3f50062374f
ENGR00240990 MX6 HDMI dongle:Configure HDMI PHY registers This patch sets HDMI PHY register values in MXC HDMI driver platform data so that MXC HDMI driver can configure the 0x09 CKSYMTXCTRL register(Clock Symbol and Transmitter Control Register) and 0x0E VLEVCTRL register(Voltage Level Control Register), then we may pass HDMI compliance test for MX6 HDMI dongle board. Signed-off-by: Liu Ying <Ying.Liu@freescale.com> (cherry picked from commit 788bcf52a2e4c37dc42e9605d31995f8dd80d674)