Commits

Sandor Yu committed 238266ea8df
ENGR00215340 HDMI PHY config adjust to pass electrical compliance test In the HDMI PHY internal, there are two register that can adjust waveform of eyediagram. 0x0e -- voltage level control; it can adjust the single end data signals; 0x09 -- define pre-emphasis factor; (it will affect the rise time and fall time of D0/D1/D2); Adjust HDMI PHY register 0x09 and 0xe for MX6DL SabreSD and MX6Q SabreSD waveform of eyediagram to pass HDMI compliance test electrical test case. Signed-off-by: Sandor Yu <R01008@freescale.com>