Thara Gopinath committed 1482d8be552
OMAP3: PM: Program correct init voltages for VDD1 and VDD2 By default the system boots up at nominal voltage for every voltage domain in the system. This patch puts VDD1 and VDD2 to the correct boot up voltage as per the opp tables specified. This patch implements this by matching the rate of the main clock of the voltage domain with the opp table and picking up the correct voltage. Signed-off-by: Thara Gopinath <thara@ti.com> Signed-off-by: Kevin Hilman <khilman@deeprootsystems.com>